| REF No |
7051 |
| Purpose |
Used to determine iron +2 and +3 ions in water. |
| Ingredients |
A) Acid Solution: Acetic acid
B) Reducing Solution: Potassium iodide.
C) Indicator: O-phenanthroline |
| Working Principle |
|
| Warnings, Precautions, Recommendations |
Danger. Causes severe skin burns and eye damage. Keep away from heat/sparks/flames/hot surfaces. – No smoking. Wear protective gloves/protective clothing/eye protection/face protection. IF SWALLOWED: Rinse your mouth. DO NOT induce vomiting. IF ON SKIN (or hair): Immediately remove all contaminated clothing. Rinse skin with water. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. |
| Application
|
1. Take the measuring cup from the kit box. Add 5 ml of water sample.
2. Add 8 drops of A-Acid Solution and mix. Wait 2 minutes.
3. Add 8 drops of B-Reducing Solution and mix. Wait 2 minutes.
4. Add 8 drops of C-Indicator Solution and mix. Wait 2 minutes. Compare the color formed with the color scale.
For Solid Samples:
1. Take the measuring cup from the kit box. Place a piece of cloth smaller than approximately 20x20mm into the cup.
2. Add 8 drops of A-Acid Solution. Stir with a toothpick. Wait 4 minutes.
3. Add 5 ml of distilled water and stir.
4. Add 8 drops of B-Reducing Solution and mix. Wait 2 minutes.
5. Add 8 drops of C-Indicator Solution and mix. Observe the color change after 2 minutes.
6. Determine whether the color matches any shade on the color scale. The result is qualitative. |
| Theoretical Results |
The resulting color is compared to the color scale.
|
| Related Media
|
|
| Shelf Life |
2 years. |
| Shelf Life After Opening the Lid |
|
| Storage Temperature |
5/25 °C |
| pH (at 25°C) |
|
| Transportation Information
|
|
| Ordering and Packaging Information |
|
Order No |
Unit |
Volume |
Packaging Type |
Quantity in a Box |
Koli İçi Miktar |
|
457051090020 |
Piece |
20 mL |
50 ml, HDPE White Bottle with Dropper |
1 |
20 |
|
| Keywords
|
|